Hi Naomi,
The assignment from InfoObject 0WBS_ELEMT to InfoObject ZXWBSELMT is not automatically proposed since the InfoObject technical names are different. Here a manual action is necessary:
- Go to the Transformation in change mode;
- Select target segment Hierarchy Structure (as shown in the screenshot);
- Either draw a line from 0WBS_ELEMT to ZXWBSELMT or define a new rule for InfoObject ZXWBSELMT (rule type "Direct Assignment" with source InfoObject 0WBS_ELEMT);
- Activate the Transformation;
- Go back to the DTP and activate it again.
In my example this was the only manual assignment which I had to make, all ohers were automatically proposed. I expect this is the only missing piece.
Best regards,
Sander